Basic Info.
Model NO.
66-1515/66-1560/66-1501/66-1701
Material
Polystyrene
Size (mm)
60*15, 90*15, 90*17, 150*15mm
Color
Clear
Sterile
Yes
Design
Vented Lid
Unit
10 Pieces/Bag, 50 Bags/Case
Total
500/Case
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
HS Code
3926909090
Production Capacity
200 Cases/Week
Product Description
Lab Supplies Plstaic PS 60/90/150 Diameter Clear Vented Lid Sterile Factory Price Petri Dishes
Feature:
I. APPLICATIONS
1. Microbiology
2. Cell growth
II. FEATURES
1. Materials: polystyrene, clear
2. EO sterilized
3. Disposable
4. Glass-like clarity
III. PETRI DISH DESIGN
1. 90 x 15mm
2. Triple-vented lid
3. Stackable
IV. PACKAGING
Bulk, 500 pieces/case (90 x 15mm)
![Lab Supplies Plstaic PS 60/90/150mm Diameter Clear Vented Lid Sterile Factory Price Petri Dishes](http://img9.grofrom.com/www.jdmedicalshop.com/226f3j00DqAkURYShWzC/Lab-Supplies-Plstaic-PS-60-90-150mm-Diameter-Clear-Vented-Lid-Sterile-Factory-Price-Petri-Dishes.webp)
![Lab Supplies Plstaic PS 60/90/150mm Diameter Clear Vented Lid Sterile Factory Price Petri Dishes](http://img9.grofrom.com/www.jdmedicalshop.com/226f3j00PodkUHYtJhzB/Lab-Supplies-Plstaic-PS-60-90-150mm-Diameter-Clear-Vented-Lid-Sterile-Factory-Price-Petri-Dishes.webp)
Ordering Information
Cat # | Material | Size (mm) | Unit | Total |
66-1560 | PS | 60x15 | 10 Pieces/Bag, 50 Bags/Case | 500/Case |
66-1501 | PS | 90x15 | 10 Pieces/Bag, 50 Bags/Case | 500/Case |
66-1515 | PS | 150x15 | 10 Pieces/Bag, 20 Bags/Case | 500/Case |
![Lab Supplies Plstaic PS 60/90/150mm Diameter Clear Vented Lid Sterile Factory Price Petri Dishes](http://img9.grofrom.com/www.jdmedicalshop.com/226f3j00LqJcfoUnAhze/Lab-Supplies-Plstaic-PS-60-90-150mm-Diameter-Clear-Vented-Lid-Sterile-Factory-Price-Petri-Dishes.webp)
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.
2. What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.
3. What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc.